Seismic control systems: (Record no. 6767)

MARC details
000 -LEADER
fixed length control field 02624nam a2200193Ia 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20191010191615.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 160802s9999 xx 000 0 und d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
ISBN 9781845646721
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title eng
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 624.1762
Item number SEI
100 ## - MAIN ENTRY--AUTHOR NAME
Personal name Syngellakis, S., ed.
245 ## - TITLE STATEMENT
Title Seismic control systems:
Remainder of title design and performance assessment /
Statement of responsibility, etc edited by S. Syngellakis
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Name of publisher WIT Pr,
Year of publication 2013.
Place of publication Southampton:
300 ## - PHYSICAL DESCRIPTION
Number of Pages ix,195 p.
505 ## - FORMATTED CONTENTS NOTE
Formatted contents note Features recent application and conditions for the correct use of seismic isolation systems by A. Martelli, M. Forni and G. Panza--<br/>State of the art of the development and application of seismic isolation and energy dissipation technologies for buildings in Japan by M. Higashino, N. Kani, Y. Ohta and H. Hamaguchi --<br/>Recent applications of Italian antiseismic devices by .M.G. Castellano and S. Infanti -- Structural applications of energy dissipation systems and seismic isolation in Cyprus by P. Komodromos and M.C. Phocas -- Mechanical devices to control limit and attenuate shocks vibrations and seismic movements in buildings equipment and piping networks by V. Serban, M. Androne, A.G. Ciocan and A.M. Zamfir -- Introducing orthogonal roller pairs as an effective isolating system for low rise buildings by M. Hosseini and K. Kangarloo -- Structures with multiple seismic isolation levels by M.C. Phocas and G. Pamboris -- On the dynamic response of hardening systems by O. Sircovich Saar -- Energybased evaluation of seismic response of structures with passive and active systems by A. Yanik, U. Aldemir and M. Bakioglu -- Aseismic study of a building with an efficiencyenhanced damping system by S.S. Ke, W.S. Li and B.J. Shih -- Seismic protection of bridges using viscous dampers by M. Spizzuoco, G. Serino and C. Onorii -- Seismic isolation for a wide span glazed roof by G.C. Giuliani and M.E. Giuliani --Analysis and assessment of a seismically isolated bridge by A.J. Kappos and E. Dimitrakopoulos -- Study of the seismic response of rc isolated elevated water tanks by V.I. Fernandez- Davila, F. Gran and P Baquedano -- Vulnerability functions and the influence of seismic design parameters on initial costs for buildings provided with hysteretic energydissipating devices by J. Garicia-Perez, M. Zenteno and O. Diaz -- Optimum design of tuned mass damper systems for seismic structures by I. Abdulsalam, M. Al- Janabi and M.G. Al- Taweel -- Generalized Den Hartog tuned mass damper system for control of vibrations in structures by I. M. Abubakar and B.J.M. Farid<br/>
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical Term AR
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Syngellakis, S., ed.
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Books
Holdings
Lost status Damaged status Collection code Home library Current library Shelving location Date acquired Source of acquisition Cost, normal purchase price Full call number Accession Number Koha item type
    Non Fiction Library, SPAB Library, SPAB H-1 02/08/2016 SPAB/LIB/2015-16/B592 | 2015-07-15 | IN11865/15-16 | 2015-09-03 | Shankar | GBP93.00 | Rs9988.20 93.00 624.1762 SEI 009146 Text/Reserve Book

Library, SPA Bhopal, Neelbad Road, Bhauri, Bhopal By-pass, Bhopal - 462 030 (India)
Ph No.: +91 - 755 - 2526805 | E-mail: [email protected]

OPAC best viewed in Mozilla Browser in 1366X768 Resolution.
Free counter