Seismic control systems: (Record no. 6767)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02624nam a2200193Ia 4500 |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20191010191615.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 160802s9999 xx 000 0 und d |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
ISBN | 9781845646721 |
041 ## - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | 624.1762 |
Item number | SEI |
100 ## - MAIN ENTRY--AUTHOR NAME | |
Personal name | Syngellakis, S., ed. |
245 ## - TITLE STATEMENT | |
Title | Seismic control systems: |
Remainder of title | design and performance assessment / |
Statement of responsibility, etc | edited by S. Syngellakis |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Name of publisher | WIT Pr, |
Year of publication | 2013. |
Place of publication | Southampton: |
300 ## - PHYSICAL DESCRIPTION | |
Number of Pages | ix,195 p. |
505 ## - FORMATTED CONTENTS NOTE | |
Formatted contents note | Features recent application and conditions for the correct use of seismic isolation systems by A. Martelli, M. Forni and G. Panza--<br/>State of the art of the development and application of seismic isolation and energy dissipation technologies for buildings in Japan by M. Higashino, N. Kani, Y. Ohta and H. Hamaguchi --<br/>Recent applications of Italian antiseismic devices by .M.G. Castellano and S. Infanti -- Structural applications of energy dissipation systems and seismic isolation in Cyprus by P. Komodromos and M.C. Phocas -- Mechanical devices to control limit and attenuate shocks vibrations and seismic movements in buildings equipment and piping networks by V. Serban, M. Androne, A.G. Ciocan and A.M. Zamfir -- Introducing orthogonal roller pairs as an effective isolating system for low rise buildings by M. Hosseini and K. Kangarloo -- Structures with multiple seismic isolation levels by M.C. Phocas and G. Pamboris -- On the dynamic response of hardening systems by O. Sircovich Saar -- Energybased evaluation of seismic response of structures with passive and active systems by A. Yanik, U. Aldemir and M. Bakioglu -- Aseismic study of a building with an efficiencyenhanced damping system by S.S. Ke, W.S. Li and B.J. Shih -- Seismic protection of bridges using viscous dampers by M. Spizzuoco, G. Serino and C. Onorii -- Seismic isolation for a wide span glazed roof by G.C. Giuliani and M.E. Giuliani --Analysis and assessment of a seismically isolated bridge by A.J. Kappos and E. Dimitrakopoulos -- Study of the seismic response of rc isolated elevated water tanks by V.I. Fernandez- Davila, F. Gran and P Baquedano -- Vulnerability functions and the influence of seismic design parameters on initial costs for buildings provided with hysteretic energydissipating devices by J. Garicia-Perez, M. Zenteno and O. Diaz -- Optimum design of tuned mass damper systems for seismic structures by I. Abdulsalam, M. Al- Janabi and M.G. Al- Taweel -- Generalized Den Hartog tuned mass damper system for control of vibrations in structures by I. M. Abubakar and B.J.M. Farid<br/> |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical Term | AR |
700 ## - ADDED ENTRY--PERSONAL NAME | |
Personal name | Syngellakis, S., ed. |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Koha item type | Books |
Lost status | Damaged status | Collection code | Home library | Current library | Shelving location | Date acquired | Source of acquisition | Cost, normal purchase price | Full call number | Accession Number | Koha item type |
---|---|---|---|---|---|---|---|---|---|---|---|
Non Fiction | Library, SPAB | Library, SPAB | H-1 | 02/08/2016 | SPAB/LIB/2015-16/B592 | 2015-07-15 | IN11865/15-16 | 2015-09-03 | Shankar | GBP93.00 | Rs9988.20 | 93.00 | 624.1762 SEI | 009146 | Text/Reserve Book |